Wednesday, July 18, 2012
Polary Meter (Analog)
Posted by
Unknown
at
12:05 AM
Polary Meter (Analoge)
Model: POL-1
Brand: OPTIKA
Technical Specifications:
Circular polarimeter using Nicol prisms, with monochrome light source
(589.3 Nm sodium bulb). Measurement range: ± 180°
Precision: 0.05% Division: 1°
Magnification: 3x Eyepiece: with fine focusing
Stabilisation time: 5 mins. approx.
Polarimeter tubes: 100 mm and 200 mm
Size: 510 x 135 x 380 mm Power supply: 230V/50Hz, 30W
Replacement parts for POL-1 polarimeter:
POL-1.1 Sodium bulb
POL-1.2 100 mm polarimeter tube
POL-1.3 200 mm polarimeter tube
Model: POL-1
Brand: OPTIKA
Technical Specifications:
Circular polarimeter using Nicol prisms, with monochrome light source
(589.3 Nm sodium bulb). Measurement range: ± 180°
Precision: 0.05% Division: 1°
Magnification: 3x Eyepiece: with fine focusing
Stabilisation time: 5 mins. approx.
Polarimeter tubes: 100 mm and 200 mm
Size: 510 x 135 x 380 mm Power supply: 230V/50Hz, 30W
Replacement parts for POL-1 polarimeter:
POL-1.1 Sodium bulb
POL-1.2 100 mm polarimeter tube
POL-1.3 200 mm polarimeter tube
Tuesday, July 17, 2012
Spectrophotometer Single Beam
Posted by
Unknown
at
5:05 AM
Spectrophotometer Single Beam
Model: OPTIZEN POP
Brand: MEACASYS
Technical Specifications:
Photometric System: Single Beam spectroscopy
Spectral Bandwidth: > 1.8nm
Wavelength:
Range: 190 ~ 1100nm
Accuracy: <± 0.5nm (at D2 Peak 656.1nm, 486.0nm)
Reproducibility: ±0.01nm
Setting: ≥0.01nm
Slew rate: about 7800nm/min
Scanning Speed: Max 4000nm/min
Photometric:
Range: -3.0 ~ 3.0 ABS (Enable to set up)/ -0.5 ~ 2.5 ABS (with Nanoliter cell)
Accuracy: ±0.005 ABS (at 1.0 ABS)
Reproducibility: ±0.003 ABS (at 1.0 ABS)
Stray right: <0.05%T (220nm, 340nm)
Baseline Stability: <±0.001 ABS/h (at 550nm)
Baseline Flatness: <±0.002 ABS/h (200 ~ 1100nm)
Light Source: Tungsten – Halogen Lamp and Deuterium Lamp
Lamp Change Wavelength: 340 ~ 410nm (Default at 370nm), include Auto Position System
Monochromatic: Modified Czerny – Turner type with 1200 lines/mm blazed grating
Standard Cell Holder:
OPTIZEN POP: Rotary type 8 position multi cell holder
OPTIZEN QX: All-in-one cell holder
OPTIZEN BIO: Micro volume cell holder
Interface: 4 USB ports / 3 RS-232C ports)
Data Capacity: 2 GB (OPTION : 8 GB)
Interacting Printer type: Network printer, USB port Type printer (Support PCL mode)
Detector: Silicon Photodiode
Power Requirement: Free Voltage
Dimension (mm): 433(W) x 381(D) x 180(H)
Weight: 8kg
Model: OPTIZEN POP
Brand: MEACASYS
Technical Specifications:
Photometric System: Single Beam spectroscopy
Spectral Bandwidth: > 1.8nm
Wavelength:
Range: 190 ~ 1100nm
Accuracy: <± 0.5nm (at D2 Peak 656.1nm, 486.0nm)
Reproducibility: ±0.01nm
Setting: ≥0.01nm
Slew rate: about 7800nm/min
Scanning Speed: Max 4000nm/min
Photometric:
Range: -3.0 ~ 3.0 ABS (Enable to set up)/ -0.5 ~ 2.5 ABS (with Nanoliter cell)
Accuracy: ±0.005 ABS (at 1.0 ABS)
Reproducibility: ±0.003 ABS (at 1.0 ABS)
Stray right: <0.05%T (220nm, 340nm)
Baseline Stability: <±0.001 ABS/h (at 550nm)
Baseline Flatness: <±0.002 ABS/h (200 ~ 1100nm)
Light Source: Tungsten – Halogen Lamp and Deuterium Lamp
Lamp Change Wavelength: 340 ~ 410nm (Default at 370nm), include Auto Position System
Monochromatic: Modified Czerny – Turner type with 1200 lines/mm blazed grating
Standard Cell Holder:
OPTIZEN POP: Rotary type 8 position multi cell holder
OPTIZEN QX: All-in-one cell holder
OPTIZEN BIO: Micro volume cell holder
Interface: 4 USB ports / 3 RS-232C ports)
Data Capacity: 2 GB (OPTION : 8 GB)
Interacting Printer type: Network printer, USB port Type printer (Support PCL mode)
Detector: Silicon Photodiode
Power Requirement: Free Voltage
Dimension (mm): 433(W) x 381(D) x 180(H)
Weight: 8kg
Spectrophotometer Double Beam
Posted by
Unknown
at
4:59 AM
Spectrophotometer Double Beam
Model: OPTIZEN Alpha
Brand: MEACASYS
Technical Specifications:
Photometric System: Double Beam spectroscopy
Spectral Bandwidth: > 1.0nm
Wavelength:
Range: 190 ~ 1100nm
Accuracy: <± 0.1nm
Slew rate: 7000nm/min
Scanning Speed: Max 4000nm/min
Photometric:
Range: -4.0 ~ 4.0 ABS
Accuracy: ±0.005 ABS (at 1.000 ABS)
Reproducibility: ±0.003 ABS (at 1.000 ABS)
Baseline Stability: <±0.001 ABS/h (at 550nm)
Baseline Flatness: <±0.002 ABS/h (200 ~ 1100nm)
Noise: 0.001 ABS
Light Source: Tungsten – Halogen Lamp and Deuterium Lamp
Lamp Change Wavelength: 340 ~ 410nm (Default at 370nm), include Auto Position System
Monochromator: Modified Czerny – Turner type with 1200 lines/mm blazed grating
Standard Cell Holder: Automatic Rotary type 8-position Multi-Cell Holder
Other Interface: Wi-Fi direct & Bluetooth
Detector: Silicon Photodiode
Power Requirement: Free Voltage
Dimension (mm): 450(W) x 430(D) x 180(H)
Operating system: Android
Weight: 15kg
Model: OPTIZEN Alpha
Brand: MEACASYS
Technical Specifications:
Photometric System: Double Beam spectroscopy
Spectral Bandwidth: > 1.0nm
Wavelength:
Range: 190 ~ 1100nm
Accuracy: <± 0.1nm
Slew rate: 7000nm/min
Scanning Speed: Max 4000nm/min
Photometric:
Range: -4.0 ~ 4.0 ABS
Accuracy: ±0.005 ABS (at 1.000 ABS)
Reproducibility: ±0.003 ABS (at 1.000 ABS)
Baseline Stability: <±0.001 ABS/h (at 550nm)
Baseline Flatness: <±0.002 ABS/h (200 ~ 1100nm)
Noise: 0.001 ABS
Light Source: Tungsten – Halogen Lamp and Deuterium Lamp
Lamp Change Wavelength: 340 ~ 410nm (Default at 370nm), include Auto Position System
Monochromator: Modified Czerny – Turner type with 1200 lines/mm blazed grating
Standard Cell Holder: Automatic Rotary type 8-position Multi-Cell Holder
Other Interface: Wi-Fi direct & Bluetooth
Detector: Silicon Photodiode
Power Requirement: Free Voltage
Dimension (mm): 450(W) x 430(D) x 180(H)
Operating system: Android
Weight: 15kg
Laminar Flow
Posted by
Unknown
at
4:56 AM
Laminar Flow
Size: 3 Feet
Model: AHC-382
Brand: ESCO
Nominal Size: 0.9 Meters (3’)
External Dimensions (W x D x H): 1035 x 750 x 1255 mm
Inter Work Area, Dimensions (W x D x H): 875 x 600 x 720 mm
Usable Work Zone: 0.43 m2 (4.6 sq.ft)
ULPA Filter Typical: >99.999% at particle size between 0.1 to 0.3 µm
Sound Emission Per IEST-RP-CC002.2: <61 dBA Fluorescent Lamp Intensity At Zero Ambient: > 1800 Lux (>167 foot candles)
Cabinet Construction:
Main Body: 1.2 mm/ 0.05”/18 gauge electro-galvanised steel with oven-baked expoxy powder-coated finish.
Work Zone: 1.5 mm (0.06”) 18 gauge stainless steel, grade 304
Side Walls: UV absorbing tempered glass, 5 mm (0.2”), colorless and transparent
Size: 3 Feet
Model: AHC-382
Brand: ESCO
Nominal Size: 0.9 Meters (3’)
External Dimensions (W x D x H): 1035 x 750 x 1255 mm
Inter Work Area, Dimensions (W x D x H): 875 x 600 x 720 mm
Usable Work Zone: 0.43 m2 (4.6 sq.ft)
ULPA Filter Typical: >99.999% at particle size between 0.1 to 0.3 µm
Sound Emission Per IEST-RP-CC002.2: <61 dBA Fluorescent Lamp Intensity At Zero Ambient: > 1800 Lux (>167 foot candles)
Cabinet Construction:
Main Body: 1.2 mm/ 0.05”/18 gauge electro-galvanised steel with oven-baked expoxy powder-coated finish.
Work Zone: 1.5 mm (0.06”) 18 gauge stainless steel, grade 304
Side Walls: UV absorbing tempered glass, 5 mm (0.2”), colorless and transparent
Autoclave Digital
Posted by
Unknown
at
3:10 AM
Autoclave Digital
Capacity: 40 Liter
Model: JSAC – 40
Brand: JSR
Origin: Korea
Technical Specifications:
Number of Rooms: 1 Room
Temperature:
Capacity: 40 Liter
Model: JSAC – 40
Brand: JSR
Origin: Korea
Technical Specifications:
Number of Rooms: 1 Room
Temperature:
Heating Type : Direct Heating by Stainless Steel Incoloy Heater
Range: up to 1230C
Accuracy: ±50C at 1210C
Uniformity: ±2.00C at 1210C
Heat up Time to 1210C : Approx 25 min
Heater Control : 3 KW
Main Controller: Digital PID Controller with Wait on/off Timer and Auto-Tuning
Wait off Timer: mm:ss / hh:mm / continuous Selectable
Sensor: Pt 100Ώ
Safety Device-Temperature: Hydraulic Over Temperature Protection Safety Device
Electrical: Electrical Leakage Breaker
Pressure: Mechanical Over pressure safety valve
Dimenstions –Inner: (I) 300xH620
Outer WxDxH mm: 710x560x1160mm
Usable: (I) 280xH600
Basket: (I) 280xH280
Basket Type: Stainless Steel Perforated Basket
# 2
Maximum Basket Load: 2
Plug Type: European 220 VAC STD Plug
Power Consumption: 13A
Electric Requirement: 220 VAC 50/60 Hz or 120 VAC 60 Hz
Range: up to 1230C
Accuracy: ±50C at 1210C
Uniformity: ±2.00C at 1210C
Heat up Time to 1210C : Approx 25 min
Heater Control : 3 KW
Main Controller: Digital PID Controller with Wait on/off Timer and Auto-Tuning
Wait off Timer: mm:ss / hh:mm / continuous Selectable
Sensor: Pt 100Ώ
Safety Device-Temperature: Hydraulic Over Temperature Protection Safety Device
Electrical: Electrical Leakage Breaker
Pressure: Mechanical Over pressure safety valve
Dimenstions –Inner: (I) 300xH620
Outer WxDxH mm: 710x560x1160mm
Usable: (I) 280xH600
Basket: (I) 280xH280
Basket Type: Stainless Steel Perforated Basket
# 2
Maximum Basket Load: 2
Plug Type: European 220 VAC STD Plug
Power Consumption: 13A
Electric Requirement: 220 VAC 50/60 Hz or 120 VAC 60 Hz
pH Meter Bench Type
Posted by
Unknown
at
2:52 AM
pH Meter Bench Type
Model: HI 2211
Brand: Hanna
SPECIFICATIONS:
Range:
Model: HI 2211
Brand: Hanna
SPECIFICATIONS:
Range:
pH -2.00 to 16.00 pH
mV : ±399.9 mV ; ±2000 mV
Temperature: -9.9 to 120.0°C
Resolution:
pH 0.01 pH
mV — 0.1 mV; 1 mV
Temperature 0.1°C
Accuracy (@20°C)
pH ±0.01 pH
mV : ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV)
Temperature: ±0.5 °C (0.0 – 100.0 °C); ±1 °C (outside) (excluding probe error)
pH Calibration: automatic, 1 or 2 points with 5 automatically recognized buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01)
Temperature Compensation automatic (with HI 7669/2W probe) or manual from -9.9 to 120°C
pH Electrode: HI 1131B, glass-body, single junction, refillable, BNC connector, 1 m cable (included)
Temperature Probe : HI 7662 with 1 m (3.3’) cable (included)
Input Impedance : 1012 Ohm
Power Supply : 12 Vdc adapter (included)
Environment: 0 to 50°C (32 to 122°F); RH max 95%
Dimensions: 240 x 182 x 74 mm (9.4 x 7.1 x 2.9”)
Weight: 1.1 Kg (2.5 lb.); kit with holder 2.5 Kg (5.5 lb.)
mV : ±399.9 mV ; ±2000 mV
Temperature: -9.9 to 120.0°C
Resolution:
pH 0.01 pH
mV — 0.1 mV; 1 mV
Temperature 0.1°C
Accuracy (@20°C)
pH ±0.01 pH
mV : ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV)
Temperature: ±0.5 °C (0.0 – 100.0 °C); ±1 °C (outside) (excluding probe error)
pH Calibration: automatic, 1 or 2 points with 5 automatically recognized buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01)
Temperature Compensation automatic (with HI 7669/2W probe) or manual from -9.9 to 120°C
pH Electrode: HI 1131B, glass-body, single junction, refillable, BNC connector, 1 m cable (included)
Temperature Probe : HI 7662 with 1 m (3.3’) cable (included)
Input Impedance : 1012 Ohm
Power Supply : 12 Vdc adapter (included)
Environment: 0 to 50°C (32 to 122°F); RH max 95%
Dimensions: 240 x 182 x 74 mm (9.4 x 7.1 x 2.9”)
Weight: 1.1 Kg (2.5 lb.); kit with holder 2.5 Kg (5.5 lb.)
Viscometer For Pesting Propertie
Posted by
Unknown
at
2:44 AM
Viscometer for Pesting Propertie
Model: RP-1
Brand: RAYPA
ADDITIONAL INFORMATION
Our viscometers are supplied as complete equipment in a suitable carrying
case. Standard accessories for each basic equipment, complete set of spindles
with storage rack, interconnecting RS232 cable, spindle guard and instructions
manual, are included in case.
REQUIREMENTS
Power: 100-240/50-60Hz
Ambient temperature: 10-40ºC
Relative Humidity: <80 %
DISPLAYED PARAMETERS
Selected speed: r.p.m.
Selected spindle: S.P.
Dynamic viscosity: mPas ó cP
% Scale (Brookfield): %
Sample temperature: ºC ó ºF
Auto range to display viscosity limits: mPas ó cP
Shear ratio S.R. (with special spindles. Only in V2 version): 1/s
Shear stress S.S. (with special spindles. Only in V2 version): N/m2 ó dyne/cm2
SPECIFICATIONS
Speeds
0.3, 0.5, 0.6, 1, 1.5, 2, 2.5, 3, 4, 5, 6,10, 12, 20, 30, 50, 60,100, 200 r.p.m.
Accuracy <0.5 % of the absolute value
Spindle
Version L: (4 spindle L1 - L2 - L3 - L4)
Version R: (6 spindle R2 - R3 - R4 - R5 - R6 - R7)
Viscosity range
Version L: 3 - 2 000 000 mPas in 76 ranges - 19 speeds with
4 spindles - (For low to medium viscosity test fluids)
Version R: 20 - 13 000 000 mPas in 114 ranges - 19 speeds with
6 spindles - (For medium to higher viscosity test fluids)
Accuracy: ± 1% of full scale Repeatability: ± 0.2%
THERMOMETER
Temperature range: -15º C to +180ºC (+5ºF to + 356 ºF)
Resolution: 0.1ºC (0.1722ºF) Accuracy: ± 0.1ºC
Model: RP-1
Brand: RAYPA
ADDITIONAL INFORMATION
Our viscometers are supplied as complete equipment in a suitable carrying
case. Standard accessories for each basic equipment, complete set of spindles
with storage rack, interconnecting RS232 cable, spindle guard and instructions
manual, are included in case.
REQUIREMENTS
Power: 100-240/50-60Hz
Ambient temperature: 10-40ºC
Relative Humidity: <80 %
DISPLAYED PARAMETERS
Selected speed: r.p.m.
Selected spindle: S.P.
Dynamic viscosity: mPas ó cP
% Scale (Brookfield): %
Sample temperature: ºC ó ºF
Auto range to display viscosity limits: mPas ó cP
Shear ratio S.R. (with special spindles. Only in V2 version): 1/s
Shear stress S.S. (with special spindles. Only in V2 version): N/m2 ó dyne/cm2
SPECIFICATIONS
Speeds
0.3, 0.5, 0.6, 1, 1.5, 2, 2.5, 3, 4, 5, 6,10, 12, 20, 30, 50, 60,100, 200 r.p.m.
Accuracy <0.5 % of the absolute value
Spindle
Version L: (4 spindle L1 - L2 - L3 - L4)
Version R: (6 spindle R2 - R3 - R4 - R5 - R6 - R7)
Viscosity range
Version L: 3 - 2 000 000 mPas in 76 ranges - 19 speeds with
4 spindles - (For low to medium viscosity test fluids)
Version R: 20 - 13 000 000 mPas in 114 ranges - 19 speeds with
6 spindles - (For medium to higher viscosity test fluids)
Accuracy: ± 1% of full scale Repeatability: ± 0.2%
THERMOMETER
Temperature range: -15º C to +180ºC (+5ºF to + 356 ºF)
Resolution: 0.1ºC (0.1722ºF) Accuracy: ± 0.1ºC
Subscribe to:
Posts (Atom)